If the time on your cloud server is incorrect despite you having set it correctly you will need to set the server to sync with an ntp server.
This can be done using the following steps:
1.Click on the clock and select "Change date and time settings.."
2. Ensure the timezone is correct and select "change time zone" and ensure "Automatically adjust clock for Daylight Saving Time" is enabled and click ok.
3. Select the "Internet Time" tab and click "Change Settings", enter ntp.blacknight.ie in the server field.
3. Ensure "Synchronize with an Internet time zone" is enabled and click "Update Now" and verify the time is correct.
In addition to this you can amend the following value in the Registry to the sample time below:
- SpecialPollInterval: 900
This values is located in the following location in the Registry:
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\services\W32Time\TimeProviders\NtpClient
Caution:
Take care when editing the registry on the system, it is possible to cause corruption and also introduce problems with incorrect modification.